Skip to main content
  • Research article
  • Open access
  • Published:

99mTc-sodium phytate is a valid alternative to the gold-standard 99mTc-sulfur colloid in the measurement of gastric emptying among healthy multi-ethnic Asian population: results of a randomized cross-over trial

Abstract

Background

It is unclear if the 99mTc-sodium phytate (99mTc-SP) is as reliable as the gold-standard 99mTc-sulfur colloid (99mTc-SC) for gastric emptying scintigraphy (GES). This study is aimed to compare the emptying rates of both radiotracers in a prospective, randomized cross-over trial and to determine the normative data of a healthy multi-ethnic Asian population.

Methods

Out of the 44 healthy individuals screened, 31 (14 females; mean age: 28.4 ± 7.0 years) were enrolled and underwent GES using the standardized egg-white meal. All participants were randomly assigned to either 99mTc-SP or 99mTc-SC on the first GES session before crossed over to the other formulation after 2 weeks.

Results

Both kits achieved the radiochemical purities of > 95%. The median rate (95th upper normative limit) of gastric emptying, reported as total gastric meal retention between 99mTc-SP and 99mTc-SC, was found to be comparable at all measured time points: 0.5 h [85.0% (96.6%) vs. 82.0% (94.0%)], 1 h [70.0% (86.4%) vs. 65.0% (86.6%)], 2 h [31.0% (55.8%) vs. 25.0% (64.4%)], 3 h [7.0% (26.3%) vs. 5.0% (29.9%)], and 4 h [3.0% (10.3%) vs. 2.0% (9.9%)]; P > 0.05. In addition, both radiotracers correlated well (Kendall’s Tau (τ) coefficient = 0.498, P < 0.001) and presented with a good agreement at the 4th-hour time frame based on the Bland-Altman plot analysis.

Conclusions

99mTc-SP is a valid radiotracer alternative to 99mTc-SC for routine GES examination. The normative values for both radiotracers have also been determined for the healthy multi-ethnic Asian population.

Trial registration

This trial was registered retrospectively in the Thai Clinical Trials Registry on May 23rd, 2020 (Identifier: TCTR20200526004; http://www.clinicaltrials.in.th/index.php?tp=regtrials&menu=trialsearch&smenu=fulltext&task=search&task2=view1&id=6296).

Peer Review reports

Background

Gastric emptying scintigraphy (GES), up to the present time, remains the gold-standard test for gastroparesis and functional dyspepsia [1]. The modus operandi of GES is a non-invasive tool to quantify the emptying of a physiologic caloric meal from the stomach into the small bowel [2, 3]. Due to its reliability, GES has become the benchmark for other diagnostic tests such as isotope breath test, magnetic resonance imaging, antro-duodenal manometry, and motility capsule [3, 4].

Since its inception in the 1960s, there have been many protocols designed to optimize GES; however, no definitive standard has yet to emerge despite the continuous efforts by various nuclear medicine societies [5, 6]. In a recently published 2020 guideline for clinical radiopharmaceuticals by the Administration of Radioactive Substances Advisory Committee (ARSAC), there are two chemical forms of technetium 99-metastable (99mTc) based radiotracers that are eligible for gastrointestinal (GI) motility studies: colloids and non-absorbable compounds [7]. Despite such specification, there is a considerably wide selection of radiotracers that belong to the colloid category. 99mTc-sulfur colloid (99mTc-SC), for example, is known as the gold-standard colloidal radiotracer for GES. It is considered as the gold-standard as recommended by the GI Council of the Society of Nuclear Medicine and Molecular Imaging (SNMMI), the American Neurogastroenterology and Motility Society (ANMS), as well as the approval by the United States’ Food and Drug Administration (FDA) agency [5, 8]. However, the widespread use of 99mTc-SC in low- and middle-income countries (LMICs) has been hindered due to its expensive price tag.

It is, therefore, attractive to have an alternative option in these countries. It is also important to note there is still a limited amount of literature on other radiotracers, and to the best of our knowledge, in vivo studies on the comparison with 99mTc-SC is non-existent. In the meantime, perhaps one of the more affordable and commercially-available radiocolloids is the 99mTc-sodium phytate (99mTc-SP). 99mTc-SP is well recognized in diagnostic imaging as a radiopharmaceutical product for liver-spleen tract examination. Studies have advocated 99mTc-SP as a suitable colloidal radiotracer for GES because it possesses good labeling stability in vitro (92% at 3 h) within an egg-based meal [9]. Generally, 99mTc-SP has been used by only several centers including in Thailand and Brazil, both of which are categorized as LMICs [10, 11].

Based on the discussion above, we aimed to objectively determine the reliability of 99mTc-SP versus 99mTc-SC for the measurement of gastric emptying rates and to define the normative values for a healthy multi-ethnic Asian population.

Methods

The study protocol has received approval from the institution’s Human Research Ethics Committee (Reference number: USM/JEPeM/15070248), following the Declaration of Helsinki. The trial was registered in the Thai Clinical Trials Registry system (Identifier: TCTR20200526004; Website: http://www.clinicaltrials.in.th). Also, this report was written in adherence to the Consolidated Standards of Reporting Trials (CONSORT) 2010 guidelines.

Study participants

Prospective participants were invited to join the study using word of mouth and advertisement. Healthy participants were screened and consecutively recruited within the campus compound (Health Campus, Universiti Sains Malaysia, Kelantan, Malaysia). All participants, aged 18 years old and above, were required to provide written informed consent before participating in the study. The exclusion criteria included those with an egg allergy, past and current history of chronic medical, psychiatric, and surgical illnesses and those currently on medication(s), which might affect the GI function.

Using a single-center, randomized cross-over trial design, each participant underwent two GES sessions with an interval period of 2 weeks. Such an approach was made to eliminate any possibility of carryover effect and to avoid significant changes in the participants’ body weight or metabolic parameters. Simple randomization between 99mTc-SC and 99mTc-SP was done by an internal medicine physician (MSZ). The participants were randomized in a 1:1 allocation, based on a randomization table generated by Microsoft® Excel (Microsoft Corp., USA) to ensure that either 99mTc-SC or 99mTc-SP is received in the first session. Subsequently, they are crossed over to the other radiotracer formulation in the second session.

Scintigraphy procedure

Quality control for both kits of 99mTc-SC (Pharmalucence, Inc., USA) and 99mTc-SP (Technephyte; Center of Molecular Research, Russia) was first performed using the Tec-Control™ Chromatography strips (Biodex Medical Systems, USA). The radiochemical analysis results showed that both radiotracers possessed similar high purity values (99.7%) indicative of excellent labeling efficiency and desirability for in vivo diagnostic testing [12].

All participants were instructed to fast for at least 4–6 h and withhold any tobacco use for at least 24 h. Upon arrival to the imaging suite, they were given a standardized low-fat solid meal comprised of 118 ml (60 kcal) of egg-white mixed with either 99mTc-SC or 99mTc-SP of 37 MBq (1 mCi). The egg-white was cooked to a scrambled consistency on a non-stick skillet and served with two slices of white bread (120 kcal), 30 g strawberry jam (75 kcal), and 120 ml water to provide bulk [5, 6]. Duration for meal ingestion was capped at 15 min but optimally within 10 min.

GES was performed using a dual-head, large field-of-view single-photon emission-computed tomography/computed tomography scanner (Discovery™ SPECT/CT NM 670 Pro; GE Healthcare, USA) with a low-energy high-resolution collimator. A small 99mTc radiolabeled marker of 0.37 MBq (10 μCi) was placed over the xiphisternum throughout the entire GES examination for repositioning purposes and region-of-interest (ROI) drawing. Static anterior and posterior images of 128 × 128 matrix were then taken simultaneously for 60 s each at standard time points (0, 0.5, 1, 2, 3, 4 h) after meal ingestion in the upright position. The energy window was centered on the photopeak for 99mTc (140 keV), with a window width of 20%. Motion correction was applied to the acquired images, and the gastric ROI was manually delineated on the Xeleris™ 3.1 Workstation (GE Healthcare, USA). A nuclear medicine physician (NMN) and a medical physicist (NT) were assigned to analyze the images obtained jointly.

Data and statistical analysis

The acquired data included the decay-corrected geometric mean of the anterior and posterior gastric counts for each time point. They were expressed as percentages of radioactivity remaining inside the whole stomach (total gastric meal retention or GMR – primary outcome). The total gastric counts at time zero (immediate GES) were normalized to 100%. Subsequently, a linearly-fitted time-activity profile for gastric emptying was generated based on the GMR datasets for each radiotracer to determine the solid-phase half-emptying time (T1/2 – secondary outcome).

The data analyses were conducted using JMP® Pro 13 (SAS Institute Inc., USA) and OriginPro 2019b (OriginLab Corp., USA) software. The descriptive data for GMRs and T1/2 were expressed in the form of upper normative limit values (90th and 95th percentile), median, interquartile range (IQR), mean, standard deviation (SD), and the mean’s 95% confidence interval (CI). The reported normative values for GMRs and T1/2 were generated from 1000 bootstrap replicates of the smoothed empirical likelihood quantile dataset, and its values were equipped with the estimated 90% CIs following the recommendation of the Clinical & Laboratory Standards Institute (CLSI) [13]. The probability of normality was evaluated using the Shapiro-Wilk test, while time-related differences in GMR and T1/2 between both radiotracers were assessed using the Wilcoxon’s Signed-Rank test for matched-pairs. Furthermore, the changes in the participants were measured during the cross-over trial regardless of the GES sequence (period effect) and performed non-parametrically using the Mann-Whitney U test.

A Bland–Altman (B-A) plot analysis was conducted to evaluate the intra-subject variation of GMRs in respective groups of 99mTc-SC and 99mTc-SP and to determine the agreement between both radiotracers. To keep it simple, we chose to analyze the 4th-hour GMR dataset only because of its high sensitivity to detect gastric dysfunction [1, 14, 15]. We also decided to adopt the modified criteria of the upper normative limit for the 4th-hour time frame (normal gastric emptying < 16% GMR versus abnormal gastric emptying ≥16% GMR), as stratified by DiBaise et al. [5, 16]. For a clinically meaningful difference, the maximum allowable mean differences in GMR value between the two radiotracers at the 4th-hour was set to no more than ±6%. The methodological agreement was defined as upper and lower 95% line of agreement (LoA) limits falling within the maximum allowable difference. Overall, P-value < 0.05 is considered as statistically significant.

As for sample size, no formal calculations were undertaken due to the exploratory nature of this study and lack of previous data (no clinical trial has evaluated the feasibility and reliability of 99mTc-SP against 99mTc-SC on GES). Therefore, we followed a general rule-of-thumb, whereby a minimum of 12 participants per trial arm was regarded as adequate to conduct a 2-period cross-over pilot study [17].

Results

Out of the 44 healthy individuals screened, 31 were selected as participants of this study and were included in the final analysis (14 females; mean age: 28.4 ± 7.0 years), while the rest were excluded from the study due to medical reasons, presence of GI symptoms, and withdrawals (Fig. 1). About two-thirds of the studied population are from the Bumiputra group, which is made up of native Malays and other indigenous ethnicities in Malaysia (71.0%; 22/31), followed by Chinese (16.1%; 5/31) and Indians (12.9%; 4/31). The participants’ overall mean weight is 65.8 ± 14.1 kg (range: 40–101 kg) and the overall mean body mass index (BMI) is 24.5 ± 4.3 kg/m2 (range: 17.1–35.3 kg/m2). The first trial arm (Group 1: 99mTc-SC, then 99mTc-SP) consisted of 18 participants while the second trial arm (Group 2: 99mTc-SP, then 99mTc-SC) comprised of 13 participants. At the baseline, there are no significant differences in sex and BMI between the two randomized groups (Table 1; P > 0.05).

Fig. 1
figure 1

Study flowchart for the randomized cross-over trial

Table 1 Baseline participants’ characteristics between groups

No activity was observed in the GI tract, except for the labeled bolus. It was also reported that all participants showed no signs of vomiting or partial ingestion of the test meal during the examination process. Figure 2 demonstrates one of the 62 paired GES images considered for analysis. The descriptive data of GMRs for 99mTc-SC and 99mTc-SP labeled meals are shown in Table 2. In brief, we found no statistically significant differences in time-related GMRs and linearly-fitted T1/2 between 99mTc-SC and 99mTc-SP (all P > 0.05). Figure 3 shows the comparison of the time-activity gastric emptying profile generated using the entire dataset of 31 participants (mean ± SD) for both radiotracers, while Fig. 4 shows its corresponding box-and-whiskers plot. The change in gastric emptying parameters between the sessions for Group 1 and Group 2 was summarized in Table 3. Statistical analysis on the cross-over design revealed no evidence of period effect across all of the investigated parameters (P > 0.05).

Fig. 2
figure 2

Paired anterior images of the 4-h gastric emptying scintigraphy protocol acquired from a healthy female participant. (a) 99mTc-SC, and (b) 99mTc-SP

Table 2 Descriptive statistics of gastric emptying scintigraphy for standardized egg-white solid-meal labeled with 99mTc-SC and 99mTc-SP
Fig. 3
figure 3

Gastric emptying profile for the 4-h standardized egg-white solid-meal labeled with 99mTc-SC (solid black line) and 99mTc-SP (dashed black line)

Fig. 4
figure 4

Box-and-whiskers plot for total gastric meal retention (GMR) and gastric emptying half time (T1/2) for standardized egg-white solid-meal labeled with 99mTc-SC (grey box) and 99mTc-SP (white box). As indicated in the brackets, there are no significant differences in GMR and T1/2 between both radiotracers (P > 0.05)

Table 3 Comparison of gastric emptying parameter outcomes based on test meal sequence

According to the B-A plot analysis (Fig. 5), it could be noted that the average difference of GMR percentages between the two radiotracers, as an estimate of the agreement, is considerably small, where on average, the measured GMR for 99mTc-SC is 0.9% ± 2.3% lower than 99mTc-SP at the 4th-hour mark. Almost all the dots (96.8%; 30/31) fell within the narrow LoAs (and the 95% CI indicated by the shaded regions) and decently clustered around the line of equality. The LoAs were also found to be within the acceptable 6% maximum allowable difference. Furthermore, there is a moderate positive correlation (Kendall’s Tau (τ) coefficient = 0.498, P < 0.001) between the 4th-hour time-point GMRs for both 99mTc-SC and 99mTc-SP.

Fig. 5
figure 5

Bland-Altman graph showing the difference of total gastric meal retention (GMR) between 99mTc-SC and 99mTc-SP the 4th-hour time frame, plotted against the mean measurements. The analysis showed a good agreement between the two radiotracers, and both limits of agreement fell within the defined maximum allowable difference of ±6%

Discussion

Using the standardized egg-based meal, our results showed that the GMRs for 99mTc-SP and 99mTc-SC are similar. The calculated normative values for each time point for 99mTc-SP are in agreement with the universally-accepted upper normal limits, i.e., 90% at 1 h, 60% at 2 h, 30% at 3 h and 10% at 4 h, and these GMR values commensurate with previous reports on 99mTc-SC [5]. We have also reported the normal values for gastric emptying T1/2, and similar to GMRs, no significant differences were found between the results for 99mTc-SP and 99mTc-SC.

The main strength of this prospective imaging study is the cross-over design, which minimized the noise from inter-subject variations and reduced the effect of small-sample statistics (fewer participants are required to achieve the same precision as a traditional parallel-group design) [18]. However, even with the intended equal randomization, an optimal within-individual comparison could not be made due to the unbalanced group sizes (5 participants from Group 2 were excluded in the final analysis). This flaw might introduce a power issue, which could hamper the study’s ability to detect and adjust for a period effect. It is clear from the outset that there are no prior reasons to anticipate a period effect as it is assumed that the healthy participants are stable over time, and they do not have any underlying chronic medical conditions. The two-week interval was also relatively short and deemed adequate to observe similar gastric emptying patterns. Nonetheless, the analysis for the period effect conducted on the available dataset showed statistically insignificant results across all of the GES parameters. Hence, it is estimated that this methodological disadvantage does not have a substantive effect on the results presented here.

The B-A plot analysis has shown that both radiotracers have a small systematic difference only, where 99mTc-SP provided a slightly higher average GMRs compared to 99mTc-SC. Additionally, the good agreement levels and correlations between the two radiotracers further support 99mTc-SP as a useful alternative to 99mTc-SC. In the absence of any previous trials comparing the two radiotracers, this study provided valid evidence that 99mTc-SP is as good as 99mTc-SC and comes at a cheaper cost.

Although considered as the gold-standard, only a handful of nuclear medicine centers around the world that can perform routine GES due to the high price of 99mTc-SC kits. In this regard, a standard Technephyte kit with five sterile vials is much more cost-effective at MYR 920 (USD 220) in comparison to the price of the Pharmalucence kit with the same number of vials, which could reach up to MYR 4860 (USD 1161). This pricing gap indicates that the use of 99mTc-SP could generate an almost 5-folds net saving of MYR 3940 (USD 940), and will be especially useful in low resource settings, i.e., in LMICs. Other advantages of Technephyte kits include not needing any boiling procedure, which simplifies the radiotracer preparation and minimizes the radiation exposure to staff members inside a hot laboratory. On top of that, any readily-available extra doses from GES can be immediately dispensed to perform other colloid-based scintigraphy procedures, i.e., lymph node mapping and liver-spleen imaging [19, 20].

A potential drawback that could arise with the use of 99mTc-SP is the small colloidal size (particle mean size: 50–150 nm), which may easily evaporate into the air during the cooking of egg-whites compared to the larger 99mTc-SC (particle mean size: 61–445 nm). This limitation could cause an unsatisfactory radiolabeling efficiency of the egg-white protein (ovalbumin) and thus affecting the test meal’s overall stability inside the human gastric fluid. In the present study, the similar gastric emptying patterns shown by both radiotracers were indirectly an indication of comparable radiolabeling stability. The reason for this may be due to the adding of radiotracers to the egg-white pre-cooking, which is compliant to the full consensus protocol. This method allows better affixation of the radiocolloid particles to the ovalbumin as the egg-white denatures, coagulates, and solidifies during the cooking process. Comparatively, adding the radiotracer during or post-cooking can reduce the radiolabeling stability and at risk of creating false-negative GES [21]. Misdiagnoses due to improperly performed GES would have a significant impact on patients’ quality of life, erode physicians’ confidence in diagnosing, and increase the burden of the healthcare system [22]. Therefore, with the data at hand, our findings suggest that the protocol ensures excellent radiolabeling stability and in vivo performance of gastric emptying parameters, at least for 99mTc-SP and 99mTc-SC.

To exclude the potential confounding effect of sex on gastric emptying [23, 24], we have performed a separate male and female subgroup analyses. Both sexes showed no significant differences in GMRs and T1/2 between 99mTc-SC and 99mTc-SP (all P > 0.05; Additional file 1). The individual data measured for all participants at the 4th-hour, regardless of sex, are well below the international GMR reference value of 10% – except for one female (99mTc-SP: 11%, 99mTc-SC: 14%). Upon review of our information sheet, it was found that the particular participant underwent both GES sessions during the luteal phase of her menstrual cycle. Hormonal effects have been proposed as a possible reason for delayed gastric emptying among premenopausal women – citing elevated levels of estrogen and progesterone during the luteal phase may inhibit smooth GI muscle activity compared to the follicular phase [25, 26]. At the moment, we are unable to appropriately compare the two phases for both radiotracers because of the limited subgroup population (see footnote a; Additional file 1). The slight emptying delay, however, remains within the pre-defined normal cut-off range (< 16% at 4th-hour), and any differences between both radiotracer measurements are unlikely to be of clinical significance.

Conclusion

In conclusion, this study shows that 99mTc-SP is a reliable alternative radiotracer to 99mTc-SC for GES. This study has also established the normative data of both radiotracers in GES for the healthy multi-ethnic Asian population.

Availability of data and materials

The minimal data that supports the conclusions of this study are included in the article. The full datasets are not publicly available due to de-identified data sharing restrictions by the Human Research Ethics Committee of Universiti Sains Malaysia. The reason is that the data contain sensitive information (hospital registration number) and are easily identifiable as they come from one single hospital. Data are, however, available from the corresponding author upon reasonable request and with permission of the Human Research Ethics Committee of Universiti Sains Malaysia.

Abbreviations

99mTc-SP:

99mTc-sodium phytate

99mTc-SC:

99mTc-sulfur colloid

GES:

Gastric emptying scintigraphy

ARSAC:

Administration of Radioactive Substances Advisory Committee

99mTc:

Technetium 99-metastable

GI:

Gastrointestinal

SNMMI:

Society of Nuclear Medicine and Molecular Imaging

ANMS:

American Neurogastroenterology and Motility Society

FDA:

Food and Drug Administration

LMIC:

Low- and middle-income countries

ROI:

Region-of-interest

GMR:

Gastric meal retention

T1/2 :

Half-emptying time

IQR:

Interquartile range

SD:

Standard deviation

CI:

Confidence interval

CLSI:

Clinical & Laboratory Standards Institute

B-A:

Bland-Altman

LoA:

Line of agreement

BMI:

Body mass index

References

  1. Maurer AH, Abell T, Bennett P, Diaz JR, Harris LA, Hasler W, et al. Appropriate use criteria for gastrointestinal transit scintigraphy. J Nucl Med. 2020;61(3):11N–7N.

    PubMed  Google Scholar 

  2. Goyal RK, Guo Y, Mashimo H. Advances in the physiology of gastric emptying. Neurogastroenterol Motil. 2019;31(4):e13546.

    Article  Google Scholar 

  3. Parkman HP. Assessment of gastric emptying and small-bowel motility: scintigraphy, breath tests, manometry, and SmartPill. Gastrointest Endosc Clin N Am. 2009;19(1):49–55.

    Article  Google Scholar 

  4. Szarka LA, Camilleri M. Methods for measurement of gastric motility. Am J Physiol-Gastrointest Liver Physiol. 2009;296(3):G461–75.

    Article  CAS  Google Scholar 

  5. Abell TL, Camilleri M, Donohoe K, Hasler WL, Lin HC, Maurer AH, et al. Consensus recommendations for gastric emptying scintigraphy: a joint report of the American Neurogastroenterology and motility society and the Society of Nuclear Medicine. J Nucl Med Technol. 2008;36(1):44–54.

    Article  Google Scholar 

  6. Watson N, Jones H. Chapman & Nakielny’s guide to radiological procedures E-book: Elsevier health sciences; 2017.

    Google Scholar 

  7. Committee AoRSA, editor. Notes for guidance on the clinical administration of radiopharmaceuticals and the use of sealed radioactive sources Edited by Committee AoRSA. England: Public Health England; 2020. p. 58.

    Google Scholar 

  8. Knight LC. Update on gastrointestinal radiopharmaceuticals and dosimetry estimates. Semin Nucl Med. 2012;42(2):138–44.

    Article  Google Scholar 

  9. Blanc F, Salaun PY, Couturier O, Querellou S, Le Duc-Pennec A, Mougin-Degraef M, et al. 99mTc ovalbumin labelled eggs for gastric emptying scintigraphy: in-vitro comparison of solid food markers. Nucl Med Commun. 2005;26(11):1021–5.

    Article  Google Scholar 

  10. Vasavid P, Chaiwatanarat T, Pusuwan P, Sritara C, Roysri K, Namwongprom S, et al. Normal solid gastric emptying values measured by scintigraphy using Asian-style meal: a multicenter study in healthy volunteers. J Neurogastroenterol Motil. 2014;20(3):371.

    Article  Google Scholar 

  11. Willegaignon J, Braga LF, Sapienza MT, Coura-Filho GB, Cardona MA, Alves CE, et al. Diagnostic reference level: an important tool for reducing radiation doses in adult and pediatric nuclear medicine procedures in Brazil. Nucl Med Commun. 2016;37(5):525–33.

    Article  Google Scholar 

  12. Fernandes RS, Mota LG, Kalbasi A, Moghbel M, Werner TJ, Alavi A, et al. 99mTc-phytate as a diagnostic probe for assessing inflammatory reaction in malignant tumors. Nucl Med Commun. 2015;36(10):1042–8.

    Article  CAS  Google Scholar 

  13. Horowitz GL, Altaie S, Boyd JC. Defining, establishing, and verifying reference intervals in the clinical laboratory; approved guideline: CLSI; 2010.

    Google Scholar 

  14. Ziessman HA, Bonta DV, Goetze S, Ravich WJ. Experience with a simplified, standardized 4-hour gastric-emptying protocol. J Nucl Med. 2007;48(4):568–72.

    Article  Google Scholar 

  15. Solnes LB, Sheikhbahaei S, Ziessman HA. EnsurePlus as an alternative to the standardized egg gastric-emptying meal. Clin Nucl Med. 2019;44(6):459–61.

    Article  Google Scholar 

  16. Dibaise J, Islam R, Dueck A, Roarke M, Crowell M. Psychological distress in Rome III functional dyspepsia patients presenting for testing of gastric emptying. Neurogastroenterol Motil. 2016;28(2):196–205.

    Article  CAS  Google Scholar 

  17. Julious SA. Sample size of 12 per group rule of thumb for a pilot study. Pharm Stat. 2005;4(4):287–91.

    Article  Google Scholar 

  18. Li T, Yu T, Hawkins BS, Dickersin K. Design, analysis, and reporting of crossover trials for inclusion in a meta-analysis. PLoS One. 2015;10(8):e0133023.

    Article  Google Scholar 

  19. Seok JW, Choi YS, Chong S, Kwon GY, Chung YJ, Kim BG, et al. Sentinel lymph node identification with radiopharmaceuticals in patients with breast cancer: a comparison of 99m Tc-tin colloid and 99m Tc-phytate efficiency. Breast Cancer Res Treat. 2010;122(2):453–7.

    Article  CAS  Google Scholar 

  20. Greiser J, Weigand W, Freesmeyer M. Metal-based complexes as Pharmaceuticals for Molecular Imaging of the liver. Pharmaceuticals. 2019;12(3):137.

    Article  CAS  Google Scholar 

  21. McKee J-LD, Farrell MB, Hunt KT, Loveless V, Brannen C. Gastric emptying scintigraphy egg radiolabeling efficiency pre-and post-microwave cooking. J Nucl Med Technol. 2019;1:118.225177.

    Google Scholar 

  22. Wise JL, Vazquez-Roque MI, McKinney CJ, Zickella MA, Crowell MD, Lacy BE. Gastric emptying scans: poor adherence to National Guidelines. Dig Dis Sci. 2020:1–10. https://0-doi-org.brum.beds.ac.uk/10.1007/s10620-020-06314-2.

  23. Gonzalez Z, Loganathan P, Sarosiek I, McCallum RW. Gender-related differences in gastroparesis. Am J Med Sci. 2020;S0002-9629(20):30148.

    Google Scholar 

  24. Kim YS, Kim N. Functional dyspepsia: a narrative review with a focus on sex-gender differences. J Neurogastroenterol Motil. 2020;26(3):322.

    Article  Google Scholar 

  25. Liu W, Jin Y, Wilde PJ, Hou Y, Wang Y, Han J. Mechanisms, physiology, and recent research progress of gastric emptying. Crit Rev Food Sci Nutr. 2020:1–14. https://0-doi-org.brum.beds.ac.uk/10.1080/10408398.2020.1784841.

  26. Caballero-Plasencia A, Valenzuela-Barranco M, Martin-Ruiz J, Herrerias-Gutierrez J, Esteban-Carretero J. Are there changes in gastric emptying during the menstrual cycle? Scand J Gastroenterol. 1999;34(8):772–6.

    Article  CAS  Google Scholar 

Download references

Acknowledgments

Elements of the present work have been presented orally at the Korea Digestive Disease Week 2019 (KDDW 2019), 28 - 30 November 2019, Seoul, Korea; and published as conference-related abstract: 99mTc-Phytate Is a Suitable Cheaper Alternative to the Gold-Standard 99mTc-Sulfur Colloid in Gastric Emptying Scintigraphy: A Validation Study among Healthy Volunteers. Gut and Liver. November 2019, Vol. 13 Issue 6 (Suppl. 1), p40-40.

We wish to thank the staff of Nuclear Medicine, Radiotherapy and Oncology Department of Hospital USM, and also other participating investigators for their assistance and input throughout the study course. Finally, we extend our appreciation to Dr. Aizaq Adham Ahmad Alwi for his involvement in coming up with the initial idea of this research.

Funding

This study was supported by the Research University Grant (1001/PPSP/812151) and the Short-term Research Grant (304/PPSP/6315121) of Universiti Sains Malaysia. The funders had no role in the study design, data collection, data analysis, interpretation, or writing of the report.

Author information

Authors and Affiliations

Authors

Contributions

NMN and LYY secured the funding. NMN, MFMR, WMNWZ, MSZ, WMS, and LYY contributed to the conception and design of the study. NMN, NT, MFMR, MSZ, and LYY collected, analyzed, and interpreted the data, as well as responsible for the manuscript drafting. NMN, NT, and LYY critically revised the paper and enhanced its intellectual content. All authors have read and approved the final version of the manuscript.

Corresponding author

Correspondence to Yeong Yeh Lee.

Ethics declarations

Ethics approval and consent to participate

The study protocol was approved by the Human Research Ethics Committee of Universiti Sains Malaysia (Reference number: USM/JEPeM/15070248). Written informed consent was obtained from all individual participants.

Consent for publication

Written informed consent for the publication of this article (including scintigraphy images) was obtained from all individual participants.

Competing interests

Author LYY is a member of the Editorial Board (Section Editor) for BMC Gastroenterology. The editorial evaluation or decision to accept this article for publication was not influenced by his position and was made independently of him. The remaining authors declare that they have no other competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary information

Additional file 1: Table S1.

Separate comparison of gastric emptying parameters according to sex subgroups.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mat Nawi, N., Tagiling, N., Mohd Rohani, M. et al. 99mTc-sodium phytate is a valid alternative to the gold-standard 99mTc-sulfur colloid in the measurement of gastric emptying among healthy multi-ethnic Asian population: results of a randomized cross-over trial. BMC Gastroenterol 20, 293 (2020). https://0-doi-org.brum.beds.ac.uk/10.1186/s12876-020-01426-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12876-020-01426-5

Keywords