Skip to main content

Comparison of operative outcomes between monopolar and bipolar coagulation in hepatectomy: a propensity score-matched analysis in a single center

Abstract

Background

Various hemostatic devices have been utilized to reduce blood loss during hepatectomy. Nonetheless, a comparison between monopolar and bipolar coagulation, particularly their usefulness or inferiority, has been poorly documented. The aim of this study is to reveal the characteristics of these hemostatic devices.

Methods

A total of 264 patients who underwent open hepatectomy at our institution from January 2009 to December 2018 were included. Monopolar and bipolar hemostatic devices were used in 160 (monopolar group) and 104 (bipolar group) cases, respectively. Operative outcomes and thermal damage to the resected specimens were compared between these groups using propensity score matching according to background factors. Multivariate logistic regression analysis was performed to identify predictive factors for postoperative complications.

Results

After propensity score matching, 73 patients per group were enrolled. The monopolar group had significantly lower total operative time (239 vs. 275 min; P = 0.013) and intraoperative blood loss (487 vs. 790 mL; P < 0.001). However, the incidence rates of ascites (27.4% vs. 8.2%; P = 0.002) and grade ≥ 3 intra-abdominal infection (12.3% vs. 2.7%; P = 0.028) were significantly higher in the monopolar group. Thermal damage to the resected specimens was significantly longer in the monopolar group (4.6 vs. 1.2 mm; P < 0.001). Use of monopolar hemostatic device was an independent risk factor for ascites (odds ratio, 5.626, 95% confidence interval 1.881–16.827; P = 0.002) and severe intra-abdominal infection (odds ratio, 5.905, 95% confidence interval 1.096–31.825; P = 0.039).

Conclusions

Although monopolar devices have an excellent hemostatic ability, they might damage the remnant liver. The use of monopolar devices can be one of the factors that increase the frequency of complications.

Peer Review reports

Background

Blood loss and transfusion during hepatic surgery increase morbidity and mortality [1]. Severe postoperative complications worsen long-term prognosis in patients with hepatic malignancy. Several surgical methods for hepatic transection and coagulation are currently available to minimize intraoperative blood loss [2, 3]. Classical resection techniques include finger fracture, sharp dissection, and crush clamping [4, 5]. Recently, an ultrasonic surgical aspirator has been used to provide a rapid and safe operative procedure [6]. Furthermore, various hemostatic coagulation and cutting devices, such as ultrasonic scalpels, have been utilized for the transection of the liver parenchyma, and advancements in these devices have been made over the past decades [7,8,9,10]. Owing to these techniques and perioperative care, the postoperative mortality rate was reduced to 3.7%. However, the morbidity rate (25.7%) remains unsatisfactory [11].

A soft coagulation system with a monopolar electrode is a novel hemostatic device that delivers a computer-controlled low voltage without electrical discharge; heat is transferred to the deeper areas of the liver while preventing the carbonization of tissues [12, 13]. However, heat injury to the remnant liver caused by this device remains a concern. Deep thermal damage may lead to liver necrosis and bile leakage postoperatively, which can result in morbidity [14].

A saline-coupled bipolar forceps coagulation system is also considered to be a safe and reliable hemostatic device to decrease intraoperative hemorrhage [15]. It has also been widely used by neurosurgeons, as it can safely cauterize small blood vessels adjacent to a nerve without causing damage if the operator does not pinch the neural tissue [16, 17]. By contrast, the coagulative effect of bipolar coagulation is weaker than that of monopolar coagulation and tends to prolong the transection time [18].

Although some studies have investigated the role of hemostatic devices in hepatic transection, a comparison between monopolar and bipolar coagulation, particularly their usefulness or inferiority, has been poorly documented [3, 15, 18]. The purpose of this retrospective cohort study was to investigate whether the monopolar device has better hemostatic efficiency than the bipolar device and whether the monopolar device increases postoperative complications.

Materials and methods

Patients

From January 2009 to December 2018, 337 consecutive patients underwent hepatic resection at Hamamatsu University School of Medicine, Japan. Eligibility criteria included a scheduled open liver resection for benign or malignant hepatobiliary disease requiring a transection of the liver parenchyma with the Cavitron Ultrasonic Surgical Aspirator (CUSA; Valleylab, Boulder, CO, USA). The hemostatic device on the cutting liver surface used saline-coupled soft coagulation of the IO advanced monopolar electrode with the VIO 300 D system (Erbe Elektromedizin GmbH, Tübingen, Germany) (monopolar group) or saline-coupled bipolar forceps coagulation with the MALIS Bipolar Electrosurgical System (CMC-III, Codman; Johnson & Johnson, New Brunswick, NJ, USA) (bipolar group) (Fig. 1). Sixty-five patients who underwent laparoscopic liver resection were excluded because the monopolar electrode was used in all cases. Three patients in whom another hemostatic device was used and five who underwent surgery without the CUSA were also excluded.

Fig. 1
figure 1

Hemostatic devices. During coagulation of the liver parenchyma, saline is dripped through the electrode tip to prevent the adherence of clots. The end of the tube is connected to a saline bottle for drip infusion. a monopolar device, b bipolar device

All patients’ data were consecutively collected during the follow-up period. The outcomes of patients who underwent monopolar coagulation were compared with those of patients who underwent bipolar coagulation. The results were analyzed using the propensity score matching (PSM) method. Postoperative complications were classified according to the Clavien-Dindo (CD) definition [19]. Ascites was considered when the patient’s body weight or the volume of drainage fluid increased or when ultrasonography or CT revealed fluid collection. Intra-abdominal infection was suspected when the patient had severe fever or when there was an elevation of inflammation markers; this was confirmed using ultrasonography or CT scan. The definitions of ascites and intra-abdominal infection are provided in Supplementary Tables 1 and 2. Additionally, the comprehensive complication index (CCI), calculated as the sum of all complications weighted based on their severity, was evaluated [20]. Informed consent for data collection was obtained using the opt-out method on the homepage of our institution’s website (https://www.hama-med.ac.jp/research/clinical-res/erc/disclosure-info/index.html). This study was approved by the ethical review board at our institution (approval number 17–124) in accordance with the ethical guidelines for clinical studies of the Japanese Ministry of Health, Labour and Welfare.

Surgical procedures

Hepatic transection was carried out using the CUSA under intermittent Pringle maneuver. This consisted of clamping the portal triad for 15 min in the case of a normal liver and 10 min in the case of liver dysfunction and releasing the clamp in both cases for 5-min intervals. The decision on the type of energy device used, such as Harmonic, LigaSure, and EnSeal vessel sealing systems, was made based on the surgeon’s preference. These energy devices are used for liver mobilization and lymph node dissection and have not been adapted for liver parenchymal transection. Small vessels (diameter < 2 mm) were ligated with thin (3–0) sutures or coagulated with electro cautery. Large vessels (diameter ≥ 2 mm) were ligated with thin (3–0) sutures. Glissonean branches of the primary or secondary trunk were doubly tied or ligated using a linear stapler. The isolated large hepatic vein was closed with a running suture or ligated using a linear stapler. During liver transection, bleeding from the cut surface was controlled using the hemostatic device, gentle compression, or suturing. To investigate bile leakage after liver transection, an intraoperative bile leak test was performed as previously reported [21].

Postoperative indication for drain removal

Drain removal criteria included the following: (1) drainage volume < 200 ml, and (2) drainage fluid was not contaminated with bile juice. If the drainage volume was > 200 ml on postoperative day 7, the drain was removed when the drain fluid was aseptic. Additionally, diuretics were administered, or the drain insertion site was sutured.

Evaluation of burned area in resected specimens

To evaluate thermal damage caused by hemostatic devices, we focused on the cutting surface of resected specimens containing the maximum tumor diameter. The specimens were fixed in 10% neutral buffered formalin. Histopathological examinations were performed in hematoxylin–eosin-stained sections. Two surgeons (SI and MT) who were blinded to any clinical information, including which hemostatic device was used, independently evaluated the burned length in resected specimens. They measured the average of three locations in formalin-fixed specimens when the edge was uniformly burned, or they measured only one location when the edge was partially burned. The average score measured by the two surgeons was adopted.

Statistical analysis

All continuous data were expressed as mean ± standard deviation (SD) or median (range, interquartile range). The Mann–Whitney U test or Student’s t-test was used to compare continuous variables. Pearson’s chi-square test or Fisher’s exact test was used to compare categorical variables. PSM was used to correct for biases in baseline variations between the two groups. Greedy matching (1:1 ratio without replacement) using a caliper width of 0.2 SD of the logit of the estimated propensity score was performed. The propensity score was calculated based on the diagnosis, background liver disease, type of resection, lymph node dissection, biliary reconstruction, neoadjuvant chemotherapy, total bilirubin level (mg/dL) (≥ 1.1 or < 1.1), aspartate transaminase level (AST, IU/L) (≥ 31 or < 31), albumin level (g/dL) (≥ 3.9 or < 3.9), prothrombin activity (≥ 69% or < 69%), activated partial thromboplastin time (≥ 69% or < 69%), hemoglobin level (g/dL) (≥ 11.4 or < 11.4), and indocyanine green retention rate at 15 min (ICGR15) (≥ 10% or < 10%) using the logistic regression model. The threshold of the test values was based on our institution’s criteria. A linear mixed-effects model for repeated measures was used to determine the association between the hemostatic device and postoperative blood examination, including levels of AST, C-reactive protein (CRP), and albumin, on each postoperative day. Paired comparisons with Bonferroni correction were used to compare pairs of postoperative days. Significant differences between hemostatic devices were analyzed using independent-sample Student’s t-test or the Welch test on each postoperative day. Multivariate logistic regression analysis was performed to identify predictive factors for postoperative complications. Odds ratio (OR) and 95% confidence interval (CI) were calculated. All calculations were carried out using SPSS Statistics software version 26 (IBM Corp., Armonk, NY, USA), and P values < 0.05 were considered significant.

Results

Patients’ characteristics before PSM

A total of 264 patients who underwent open hepatectomy were classified according to the type of hemostatic device used into the monopolar and bipolar groups (Fig. 2). Almost all patients were Japanese, except for one who was Chinese. Before November 2011, 104 patients were operated on using bipolar forceps as coagulation device. From December 2011 to December 2018, 160 patients were operated on using monopolar coagulation. The energy devices used for liver mobilization and lymph node dissection included Harmonic, LigaSure, and EnSeal vessel sealing systems; however, these were not used for liver parenchymal transection. Table 1 presents the patient background, type of surgical procedure, and laboratory data of the two groups. Some significant differences were observed between the two groups in terms of diagnosis, lymph node dissection, biliary reconstruction, AST level, albumin level, prothrombin activity, activated partial thromboplastin time, hemoglobin level, and ICGR15.

Fig. 2
figure 2

Flow diagram for the study. CUSA, Cavitron Ultrasonic Surgical Aspirator; PSM, propensity score matching

Table 1 Patient characteristics before propensity score matching

Patients’ characteristics after PSM

Because differences in preoperative parameters have the potential to affect the postoperative course after liver resection, PSM was performed between the two groups. After matching, 73 well-balanced patients in each group demonstrated similar results (Table 2).

Table 2 Patient characteristics after propensity score matching

Intraoperative outcomes and postoperative blood examination

Table 3 shows the intraoperative outcomes after PSM. The total operative time (239 [74–673] vs. 275 [89–562] min; P = 0.013), volume of blood loss (487 [0–3275] vs. 790 [145–8030] mL; P < 0.001), and volume of red blood cell transfusion (0 [0–1120] vs. 0 [0–3360] mL; P = 0.002) were significantly higher in the bipolar group than in the monopolar group. Statistical interactions between hemostatic device and postoperative day were shown for each parameter, including AST, CRP, and albumin (Table 4). All statistical differences in AST between each postoperative day were significant (Fig. 3a, Tables 4 and 5), except from days 5 to 7. The AST level on each postoperative day was significantly higher in the monopolar group than in the bipolar group (Fig. 3a, Table 4). When focusing on postoperative day 5, the level of CRP was significantly higher in the monopolar group than in the bipolar group (Fig. 3b, Table 4). Nutritional status was significantly poorer in the monopolar group than in the bipolar group on postoperative days 1, 3, 5, and 7 (Fig. 3c, Table 4).

Table 3 Intraoperative outcomes
Table 4 Linear mixed-effects model analysis between hemostatic device and postoperative day for each parameter
Fig. 3
figure 3

Postoperative blood examination. Postoperative blood examinations are shown as a black line for the monopolar group and a dotted black line for the bipolar group. Error bars indicate standard error. Asterisks indicate significance (*P < 0.05)

Table 5 Postoperative aspartate transaminase course

Incidence and severity of postoperative morbidity

Throughout the postoperative course, the overall postoperative complication rates and the incidence rates of severe clinically relevant complications (CD grade ≥ 3) tended to be higher in the monopolar group than in the bipolar group (63.0% vs. 47.9%, P = 0.067, and 24.7% vs. 13.7%, P = 0.093, respectively; Table 6). Moreover, the prevalence of ascites was significantly higher in the monopolar group than in the bipolar group (27.4% vs. 8.2%; P = 0.002). Severe intra-abdominal infection occurred more frequently as a complication in the monopolar group than in the bipolar group (12.3% vs. 2.7%; P = 0.028). Furthermore, the severity of postoperative morbidity, as evaluated using the CCI score, was significantly higher in the monopolar group than in the bipolar group (8.7 [0.00–100] vs. 0.0 [0.00–52.4]; P = 0.032).

Table 6 Postoperative outcomes

Risk factors for ascites and grade ≥ 3 intra-abdominal infection

Clinical characteristics stratified by ascites are presented in Table 7. Diagnosis, background liver condition, prothrombin activity (≥ 69% or < 69%), platelet count (≥ 15.3 × 104/μL or < 15.3 × 104/μL), Child–Pugh score, and hemostatic device use were identified as significant risk factors for ascites in the univariate analysis. Multivariate logistic regression analysis showed that the type of hemostatic device used (OR 5.626; 95% CI 1.881–16.827; P = 0.002) was an independent risk factor. The association between grade ≥ 3 intra-abdominal infection and perioperative characteristics is shown in Table 8. The results indicated that lymph node dissection (OR 8.661; 95% CI 1.985–37.794; P = 0.004), AST level (≥ 31 or < 31 IU/L) (OR 0.151; 95% CI 0.028–0.823; P = 0.029), and type of hemostatic device used (OR 5.905; 95% CI 1.096–31.825; P = 0.039) were independent risk factors for postoperative complications.

Table 7 Univariate and multivariate analyses for predicting ascites
Table 8 Univariate and multivariate analyses for predicting grade ≥ 3 intra-abdominal infection

Thermal damage to the resected specimens

The degree of thermal damage was assessed in 146 resected specimens as an alternative measure of thermal damage to the remnant liver. Severe damage, including hepatocellular degeneration, dilatation of the sinusoidal space, crush degeneration of Glisson’s sheath, hemorrhage, and hyperemia, was detected in the white zone (Fig. 4a–d). The thermal damage observed when using a monopolar hemostatic device was significantly longer than that identified when using a bipolar hemostatic device (4.6 [0.0–13] vs. 1.2 [0.0–9.3] mm; P < 0.001) (Fig. 4e). Moreover, when the length of thermal damage was divided into two groups (namely, short [< 4 mm, 93 cases] and long [≥ 4 mm, 53 cases]), the incidence of ascites in the long thermal damage group was significantly higher than that in the short thermal damage group (26.4% vs. 10.8%; P = 0.014) (Fig. 4f). The frequency of intra-abdominal abscess also tended to be higher in the long thermal damage group than in the short thermal damage group (17.0% vs. 7.5%; P = 0.079) (Fig. 4g).

Fig. 4
figure 4

Histopathological examination of thermal damage to the resected specimens. a Macroscopic findings revealed that the burned area was divided into two areas from a “white zone” to a “gray zone.” The area between the “gray zone” and tumors was recognized as the “normal zone.” The measurement of the burned area is shown with the black line. b Illustration of macroscopic findings. c The black dotted line indicates the border between the “white zone” and “gray zone.” Scale bar: 1 mm. d Hepatocellular degeneration, dilatation of the sinusoidal space, crush degeneration of Glisson’s sheath, hemorrhage, and hyperemia were observed in the “white zone.” Scale bar: 250 μm. e Thermal damage length in the resected specimens caused by hemostatic devices. Horizontal lines denote median values; boxes denote the interquartile range; whiskers denote minimum and maximum values. f Incidence rate of ascites. g Incidence rate of intra-abdominal abscess. Asterisks indicate significance (*P < 0.05)

Discussion

Our results indicate that the monopolar device led to higher postoperative complications than the bipolar device. This study showed that the incidence of all-grade ascites and grade ≥ 3 intra-abdominal infection was significantly higher after utilizing the monopolar device than after utilizing the bipolar device. Notably, the CCI score was significantly higher in the monopolar group than in the bipolar group.

Previous studies reported that the monopolar device was efficient and safe for decreasing surgical time and surgical bleeding without increasing complications compared with the bipolar device [12, 13]. However, caution concerning the monopolar device was advised when hyperthermia during surgery, widespread burn injury to the remnant liver, and increased postoperative transaminase level became evident. Another point of concern with the monopolar device was delayed-onset postoperative complications possibly caused by burn injury; however, no increase in major complications was observed [12]. The reason for this mismatch has not been proven.

A meta-analysis revealed that perioperative blood transfusion was associated with an elevated risk of death, recurrence, and postoperative complications in patients with hepatocellular carcinoma [22]. These findings emphasize the need for performing surgical techniques meticulously to minimize blood loss. Several methods, such as hepatic transection using the CUSA, Harmonic, LigaSure, and EnSeal sealing vessel systems, vascular occlusion via the Pringle maneuver, and intraoperative low central venous pressure, have been adopted to reduce blood loss and blood transfusion [2,3,4, 6,7,8, 10, 23,24,25,26]. By contrast, when bleeding occurs from the cut surface of the liver, a hemostatic device is needed. Several hemostatic devices, such as ones providing soft coagulation with a monopolar electrode, a monopolar floating ball (TissueLink; Salient Surgical Technologies, Inc., Portsmouth, NH, USA), a Coolinside device (Apeiron Medical, Valencia, Spain), and the bipolar forceps coagulation, have been used clinically in recent years [3, 15, 18, 27, 28]. Bipolar cautery also offers advantages in terms of reduced blood loss during hepatectomy and shortened operation time [29, 30]. Each device has its own advantage; however, to date, there is no consensus on the ideal method for hepatectomy. Therefore, hepatic surgeons select the hemostatic device according to their preference. This study aimed to clarify the advantages or disadvantages of the monopolar and bipolar coagulation devices for hemostasis during hepatectomy and postoperative complications.

We noticed several biases in terms of patient characteristics between the two groups. To minimize bias, PSM was performed according to the background liver disease, preoperative liver functions, and type of surgical procedures. This statistical procedure has been widely applied to analyze groups with different backgrounds [3, 31, 32]. The type of the energy devices was not included as a parameter in PSM and would not have affected the hepatectomy result because these devices were used only for liver mobilization and lymph node dissection, and liver parenchymal transection was performed using CUSA and manual ligation. After matching, the monopolar group showed a reduction in blood loss, transfusion volume, and total operative time. This finding indicated that the monopolar hemostatic device provided a stronger and quicker coagulative effect than the bipolar hemostatic device. On the contrary, increases in the level of AST were more frequently observed in the monopolar group than in the bipolar group. The monopolar system uses a computer-controlled low voltage level without electrical discharge, and therefore, heat is transferred to the deeper areas of the liver [12, 13]. By contrast, the bipolar system can cauterize only active bleeding between the forceps without adjacent tissue damage [16, 17]. Moreover, thermal damage to the deep cut surface of the liver can be avoided. As previously reported, when a monopolar system was continuously used during transection, hyperthermic and widespread burn injury to the remnant liver surface occurred, which can increase the postoperative transaminase levels or cause other unexpected liver dysfunctions [12, 13].

Next, we considered the individual complications associated with heat injury. One of the most critical complications after hepatectomy is an intra-abdominal infection. In the present study, a significant increase in severe intra-abdominal infection was observed in the monopolar group. However, no statistical difference in biliary leaks was detected between the two groups. Minor bile duct damage undetectable by the bile leak test may be caused by heat injury. A previous study revealed a significant increase in bile leakage with the use of a monopolar hemostatic device [33]. Another study reported a major bile duct injury caused by prolonged exposure to heat produced by the monopolar device [34]. By contrast, bipolar coagulation can prevent deep parenchymal necrosis and bile leakage induced by deep biliary necrosis [35, 36]. In a pig model, histological examination revealed that the thermal damage caused by the monopolar device was deeper than 10 mm, whereas the damage caused by the bipolar device was 2–3 mm deep [14]. In our study, the extent of thermal damage to the resected specimens was also greater in the monopolar group than in the bipolar group. Additionally, the incidence of intra-abdominal infection tended to be higher in the long thermal damage group.

Another individual complication of concern is ascites. In our study, the rate of ascites was significantly higher in the monopolar group than in the bipolar group. Damage to the remnant liver caused by monopolar devices could delay liver regeneration and prolong alleviation of inflammation, potentially leading to higher incidence rates of ascites. A previous study revealed that liver dysfunction, including low levels of serum albumin and platelet count, is a prognostic factor for the prevalence of ascites [37]. As discussed so far, extensive damage to the remnant liver can worsen liver reserve capacity and result in increase in ascites incidence.

Complications after hepatectomy are complex and are closely related to surgical manipulations, anesthesia technique, preoperative evaluation, and postoperative management [38]. In this study, multivariate analysis identified numerous clinical parameters as risk factors for ascites or severe intra-abdominal infection. Surprisingly, the type of hemostatic device used was an independent risk factor for both complications.

Finally, we assessed the overall morbidity using the CCI score, which is calculated based on the complication grading by CD classification and integrates every complication occurring after an intervention [20]. The overall morbidity is rated from 0 (no complication) to 100 (death). CD classification includes only the most serious complications; conversely, the CCI score summarizes the total postoperative complication rate associated with a surgical procedure even when multiple complications occur [39]. The CCI score is considered to be more sensitive than the CD classification when reporting postoperative morbidity in liver surgery [40]. Based on the CCI score, the severity of total complications in the monopolar group was significantly higher than that in the bipolar group. However, postoperative complications are affected by various factors other than operative procedures, energy devices, or hemostatic devices. Prospective validation study is necessary to elucidate our results.

This study has some potential limitations. First, the historical background was different; a bipolar device was used from 2009 to 2011, whereas a monopolar device was used from 2011 to 2018. The chief surgeon (TS) was the same during the entire study period, and the indications for hepatic resection and choice of procedure were decided under constant criteria. However, a learning curve in the surgical techniques and other confounders might have affected the outcomes. Second, the data were derived from a retrospective single-center cohort with a small sample size. Third, because the propensity score is a summary of measured covariates, it cannot eliminate unmeasured confounding factors. It is also difficult to completely eliminate arbitrariness by statistical adjustment. Finally, thermal damage to the resected specimens does not always correspond to damage to the remnant liver. Taking this into consideration, the results of this study should be verified by other large-scale series or multicenter randomized controlled trials. Thus, we are planning to conduct a multicenter randomized controlled trial based on this retrospective cohort study.

The results of this study may elucidate the impact of hemostatic devices and can aid surgeons in properly using surgical devices. Indeed, considering the spread of heat injury, the monopolar system should be carefully used only for pinpoint hemostasis. Furthermore, this device should not be used near the main Glissonean pedicle to prevent intra-abdominal infection or bile leakage.

Conclusion

Although monopolar devices have an excellent hemostatic capacity, they may cause more damage to the remnant liver. The use of monopolar devices can be one of the factors that increase the frequency of complications, such as intra-abdominal infection and ascites, compared with the use of bipolar devices.

Availability of data and materials

All data generated or analyzed during this study are included in this published article.

Abbreviations

CUSA:

Cavitron ultrasonic surgical aspirator

PSM:

Propensity score matching

CD:

Clavien-Dindo

CCI:

Comprehensive complication index

SD:

Standard deviation

AST:

Aspartate transaminase

ICGR15:

Indocyanine green retention rate at 15 min

CRP:

C-reactive protein

OR:

Odds ratio

CI:

Confidence interval

References

  1. Latchana N, Hircarra DH, Hallet J, Karanicolas PJ. Red blood cell transfusion in liver resection. Langenbecks Arch Surg. 2019;404:1–9.

    Article  Google Scholar 

  2. Romano F, Franciosi C, Caprotti R, Uggeri F, Uggeri F. Hepatic surgery using the Ligasure vessel sealing system. World J Surg. 2005;29:110–2.

    Article  Google Scholar 

  3. Hamada T, Nanashima A, Yano K, Sumida Y, Hiyoshi M, Imamura N, et al. Significance of a soft-coagulation system with monopolar electrode for hepatectomy: a retrospective two-institution study by propensity analysis. Int J Surg. 2017;45:149–55.

    Article  Google Scholar 

  4. Pachter HL, Spencer FC, Hofstetter SR, Coppa GF. Experience with the finger fracture technique to achieve intra-hepatic hemostasis in 75 patients with severe injuries of the liver. Ann Surg. 1983;197:771–8.

    Article  CAS  Google Scholar 

  5. Gurusamy KS, Pamecha V, Sharma D, Davidson BR. Techniques for liver parenchymal transection in liver resection. Cochrane Database Syst Rev. 2009;1:CD006880.

    Google Scholar 

  6. Doklestic K, Karamarkovic A, Stefanovic B, Stefanovic B, Milic N, Gregoric P, et al. The efficacy of three transection techniques of the liver resection: a randomized clinical trial. Hepatogastroenterology. 2012;59:1501–6.

    PubMed  Google Scholar 

  7. Arru M, Pulitanò C, Aldrighetti L, Catena M, Finazzi R, Ferla G. A prospective evaluation of ultrasonic dissector plus harmonic scalpel in liver resection. Am Surg. 2007;73:256–60.

    Article  Google Scholar 

  8. Gotohda N, Yamanaka T, Saiura A, Uesaka K, Hashimoto M, Konishi M, Shimada K. Impact of energy devices during liver parenchymal transection: a multicenter randomized controlled trial. World J Surg. 2015;39:1543–9.

    Article  Google Scholar 

  9. Hanyong S, Wanyee L, Siyuan F, Hui L, Yuan Y, Chuan L, et al. A prospective randomized controlled trial: comparison of two different methods of hepatectomy. Eur J Surg Oncol. 2015;41:243–8.

    Article  Google Scholar 

  10. Nanashima A, Abo T, Arai J, Takagi K, Matsumoto H, Takeshita H, et al. Usefulness of vessel-sealing devices combined with crush clamping method for hepatectomy: a retrospective cohort study. Int J Surg. 2013;11:891–7.

    Article  Google Scholar 

  11. Yokoo H, Miyata H, Konno H, Taketomi A, Kakisaka T, Hirahara N, et al. Models predicting the risks of six life-threatening morbidities and bile leakage in 14,970 hepatectomy patients registered in the National Clinical Database of Japan. Medicine (Baltimore). 2016;95:e5466.

    Article  Google Scholar 

  12. Hirokawa F, Hayashi M, Miyamoto Y, Iwamoto M, Tsunematsu I, Asakuma M, et al. A novel method using the VIO soft-coagulation system for liver resection. Surgery. 2011;149:438–44.

    Article  Google Scholar 

  13. Itoh S, Fukuzawa K, Shitomi Y, Okamoto M, Kinoshita T, Taketomi A, et al. Impact of the VIO system in hepatic resection for patients with hepatocellular carcinoma. Surg Today. 2012;42:1176–82.

    Article  Google Scholar 

  14. Ikeda T, Akahoshi T, Kawanaka H, Uchiyama H, Yamashita YI, Morita M, et al. Optimum hepatic parenchymal dissection to prevent bile leak: a comparative study using electrosurgical and stapling devices in swine. Fukuoka Igaku Zasshi. 2013;104:507–14.

    PubMed  Google Scholar 

  15. Guo JY, Li DW, Liao R, Huang P, Kong XB, Wang JM, et al. Outcomes of simple saline-coupled bipolar electrocautery for hepatic resection. World J Gastroenterol. 2014;20:8638–45.

    Article  Google Scholar 

  16. Robinson AM, Fishman AJ, Bendok BR, Richter CP. Functional and physical outcomes following use of a flexible CO2 laser fiber and bipolar electrocautery in close proximity to the rat sciatic nerve with correlation to an in vitro thermal profile model. Biomed Res Int. 2015;2015:280254.

    CAS  PubMed  PubMed Central  Google Scholar 

  17. Tokugawa J, Ogura K, Yatomi K, Kudo K, Hishii M, Tanikawa R, et al. Bipolar cutting method: another technique for harvesting donor artery with histological investigation. Oper Neurosurg (Hagerstown). 2018;14:16–9.

    Article  Google Scholar 

  18. Torzilli G, Donadon M, Marconi M, Procopio F, Palmisano A, Del Fabbro D, et al. Monopolar floating ball versus bipolar forceps for hepatic resection: a prospective randomized clinical trial. J Gastrointest Surg. 2008;12:1961–6.

    Article  Google Scholar 

  19. Dindo D, Demartines N, Clavien PA. Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg. 2004;240:205–13.

    Article  Google Scholar 

  20. Slankamenac K, Graf R, Barkun J, Puhan MA, Clavien PA. The comprehensive complication index: a novel continuous scale to measure surgical morbidity. Ann Surg. 2013;258:1–7.

    Article  Google Scholar 

  21. Sakaguchi T, Suzuki A, Unno N, Morita Y, Oishi K, Fukumoto K, et al. Bile leak test by indocyanine green fluorescence images after hepatectomy. Am J Surg. 2010;200:e19–23.

    Article  Google Scholar 

  22. Liu L, Wang Z, Jiang S, Shao B, Liu J, Zhang S, et al. Perioperative allogenenic blood transfusion is associated with worse clinical outcomes for hepatocellular carcinoma: a meta-analysis. PLoS ONE. 2013;8:e64261.

    Article  CAS  Google Scholar 

  23. Wang WD, Liang LJ, Huang XQ, Yin XY. Low central venous pressure reduces blood loss in hepatectomy. World J Gastroenterol. 2006;12:935–9.

    Article  Google Scholar 

  24. Takayama T, Makuuchi M, Kubota K, Harihara Y, Hui AM, Sano K, et al. Randomized comparison of ultrasonic vs clamp transection of the liver. Arch Surg. 2001;136:922–8.

    Article  CAS  Google Scholar 

  25. Pai M, Jiao LR, Khorsandi S, Canelo R, Spalding DR, Habib NA. Liver resection with bipolar radiofrequency device: Habib 4X. HPB (Oxford). 2008;10:256–60.

    Article  Google Scholar 

  26. Lesurtel M, Lehmann K, de Rougemont O, Clavien PA. Clamping techniques and protecting strategies in liver surgery. HPB (Oxford). 2009;11:290–5.

    Article  Google Scholar 

  27. Ishiko T, Inomata Y, Beppu T, Asonuma K, Okajima H, Takeiti T, et al. An improved technique for liver transection using a new device for soft coagulation in living donor hepatectomy. Hepatogastroenterology. 2012;59:1907–10.

    PubMed  Google Scholar 

  28. Quesada R, Poves I, Berjano E, Vilaplana C, Andaluz A, Moll X, et al. Impact of monopolar radiofrequency coagulation on intraoperative blood loss during liver resection: a prospective randomised controlled trial. Int J Hyperthermia. 2017;33:135–41.

    Article  Google Scholar 

  29. Rocca A, Cipriani F, Belli G, Berti S, Boggi U, Bottino V, et al. The Italian Consensus on minimally invasive simultaneous resections for synchronous liver metastasis and primary colorectal cancer: a Delphi methodology. Updates Surg. 2021;73:1247–65.

    Article  Google Scholar 

  30. Kamarajah SK, Wilso CH, Bundred JR, Lin A, Sen G, Hammon JS, et al. A systemic review and network meta-analysis of parenchymal transection techniques during hepatectomy: an appraisal of current randomized controlled trials. HPB (Oxford). 2020;22:204–14.

    Article  Google Scholar 

  31. Nishizuka SS, Tamura G, Nakatochi M, Fukushima N, Ohmori Y, Sumida C, et al. Helicobacter pylori infection is associated with favorable outcome in advanced gastric cancer patients treated with S-1 adjuvant chemotherapy. J Surg Oncol. 2018;117:947–56.

    Article  CAS  Google Scholar 

  32. Chhatriwalla AK, Amin AP, Kennedy KF, House JA, Cohen DJ, Rao SV, et al. Association between bleeding events and in-hospital mortality after percutaneous coronary intervention. JAMA. 2013;309:1022–9.

    Article  CAS  Google Scholar 

  33. Kaibori M, Shimizu J, Hayashi M, Nakai T, Ishizaki M, Matsui K, et al. Late-onset bile leakage after hepatic resection. Surgery. 2015;157:37–44.

    Article  Google Scholar 

  34. Gerlach TW, Troppmann C, Khatri VP. Major bile duct injury resulting from radiofrequency-assisted hepatectomy. Hepatogastroenterology. 2009;56:610–4.

    PubMed  Google Scholar 

  35. Takahashi H, Akyuz M, Aksoy E, Aucejo F, Quintini C, Miller C, et al. A new technique for hepatic parenchymal transection using an articulating bipolar 5 cm radiofrequency device: results from the first 100 procedures. HPB (Oxford). 2018;20:829–33.

    Article  Google Scholar 

  36. Yamamoto T, Uenishi T, Kaneda K, Okawa M, Tanaka S, Kubo S. Secure, low-cost technique for laparoscopic hepatic resection using the crush-clamp method with a bipolar sealer. Asian J Endosc Surg. 2017;10:96–9.

    Article  Google Scholar 

  37. Yoshikawa T, Nomi T, Hokuto D, Yasuda S, Kawaguchi C, Yamada T, et al. Risk factor for postoperative ascites in patients undergoing liver resection for hepatocellular carcinoma. World J Surg. 2017;41:2095–100.

    Article  Google Scholar 

  38. Jin S, Fu Q, Wuyun G, Wuyun T. Management of post-hepatectomy complications. World J Gastroenterol. 2013;19:7983–91.

    Article  Google Scholar 

  39. de la Plaza LR, Ramia Ángel JM, Bellón JM, Arteaga Peralta V, García Amador C, López Marcano AJ, et al. Clinical validation of the comprehensive complication index as a measure of postoperative morbidity at a surgical department: a prospective study. Ann Surg. 2018;268:838–44.

    Article  Google Scholar 

  40. Giani A, Cipriani F, Famularo S, Donadon M, Bernasconi DP, Ardito F, et al. Performance of comprehensive complication index and Clavien-Dindo complication scoring system in liver surgery for hepatocellular carcinoma. Cancers (Basel). 2020;12:3868.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

RM and YM drafted and wrote the manuscript. RM, YM, and HT were involved in study design and data interpretation. RM, YM, SI, RK, SF, MT, HK, YH, AF, TS, MF, and HT were involved in data acquisition. RM, YM, and EO analyzed the data. All authors read and approved the manuscript.

Corresponding author

Correspondence to Yoshifumi Morita.

Ethics declarations

Ethics approval and consent to participate

Informed consent for data collection was obtained using the opt-out method on the homepage of our institution’s website (https://www.hama-med.ac.jp/research/clinical-res/erc/disclosure-info/index.html). This study was approved by the ethical review board at Hamamatsu University School of Medicine (approval number 17–124) in accordance with the ethical guidelines for clinical studies of the Japanese Ministry of Health, Labour and Welfare.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1

. Supplementary Table 1. Classification of surgical complications for ascites. Supplementary Table 2. Classification of surgical complications for intra-abdominal infection.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Muraki, R., Morita, Y., Ida, S. et al. Comparison of operative outcomes between monopolar and bipolar coagulation in hepatectomy: a propensity score-matched analysis in a single center. BMC Gastroenterol 22, 154 (2022). https://0-doi-org.brum.beds.ac.uk/10.1186/s12876-022-02231-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12876-022-02231-y

Keywords